Advertisement

Table 12. B200xxxx Logical partition SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
B200 xxxx Error
Code
Description
6012
During the startup of a partition, the
partition LID failed to completely
load into the partition main storage
area.
6015
A problem occurred during the
startup of a partition. The load
source media is corrupted or not
valid.
6025
A problem occurred during the
startup of a partition. This is a
problem with the load source media
being corrupt or not valid.
6027
During the startup of a partition, a
failure occurred when allocating
memory for an internal object used
for firmware module load
operations.
6110
A problem occurred during the
startup of a partition. There was an
error on the load source device. The
startup will attempt to continue.
690A
During the startup of a partition, an
error occurred while copying open
firmware into the partition load area.
7200
Informational system log entry only.
8080
Informational system log entry only.
8081
During the startup of a partition, an
internal firmware time-out occurred;
the partition might continue to start
up but it can experience problems
while running.
8105
During the startup of a partition,
there was a failure loading the VPD
areas of the partition; the load source
media has been corrupted or is
unsupported on this server.
8106
A problem occurred during the
startup of a partition. The startup
will not continue.
8107
During the startup of a partition,
there was a problem getting a
segment of main storage in the blade
server main storage.
36
JS12 Type 7998: Problem Determination and Service Guide
Action
Go to "Isolating firmware problems" on page 222.
Replace the load source media.
Replace the load source media.
1. Make sure that enough main storage was allocated to
the partition.
2. Retry the operation.
Look for other errors and resolve them.
Go to "Isolating firmware problems" on page 222.
No corrective action is required.
No corrective action is required.
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
Replace the load source media.
Check for server firmware updates; then, install the
updates if available.

Advertisement

Table of Contents
loading

Table of Contents