IBM BladeCenter JS12 Problem Determination And Service Manual page 162

Ibm power6 architecture
Table of Contents

Advertisement

Table 23. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
651-786
304 214
651-789
2CD 214
651-78A
2CE 214
651-78B
2CC 214
651-809
651-810
2E2
651-811
2E2
651-813
651-818
651-820
2E1
651-821
2E1
651-822
2E1
651-831
2E2
651-832
G2E1
148
JS12 Type 7998: Problem Determination and Service Guide
Description and Action
Uncorrectable memory error. Go to "Performing the checkout procedure" on page
187.
Uncorrectable memory error. Go to "Performing the checkout procedure" on page
187.
Uncorrectable memory error. Go to "Performing the checkout procedure" on page
187.
Uncorrectable memory error. Go to "Performing the checkout procedure" on page
187.
Power fault warning due to unspecified cause.
Go to "Performing the checkout procedure" on page 187.
Over-voltage condition was detected.
Do the following procedure before replacing any FRUs:
1. Shut the system down.
2. Visually inspect the power cables and reseat the connectors.
3. Run the following command diag -Avd sysplanar0. When the Resource Repair
Action menu displays, select sysplanar0.
Under voltage condition was detected
Do the following procedure before replacing any FRUs:
1. Shut the system down.
2. Visually inspect the power cables and reseat the connectors.
3. Run the following command diag -Avd sysplanar0. When the Resource Repair
Action menu displays, select sysplanar0.
System shutdown due to loss of ac power to the site. System resumed normal
operation, no action required.
Power fault due to manual activation of power-off request. Resume normal
operation.
An over-temperature condition was detected.
1. Make sure that:
v The room ambient temperature is within the system operating environment
v There is unrestricted air flow around the system
2. Replace the system-board and chassis assembly.
System shutdown due to an over maximum temperature condition being reached.
1. Make sure that:
v The room ambient temperature is within the system operating environment
v There is unrestricted air flow around the system
2. Replace the system-board and chassis assembly.
System shutdown due to over temperature condition and fan failure. Use the
physical FRU location(s) as the probable cause(s). Use the physical location codes to
replace the FRUs that are identified on the diagnostics problem report screen.
Sensor detected a voltage outside of the normal range. Go to "Performing the
checkout procedure" on page 187.
Sensor detected an abnormally high internal temperature. Make sure that:
1. The room ambient temperature is within the system operating environment.
2. There is unrestricted air flow around the system.
3. There are no fan failures.

Advertisement

Table of Contents
loading

Table of Contents