Table 6. 6xxxyyyy SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
6xxxyyyy
Description
Error Codes
632BCFC7
A virtual optical device
detected an error reported by
the Network File System
server that cannot be
recovered.
632BCFC8
A virtual optical device
encountered a non-recoverable
error.
632CC000
Informational system log entry
only.
632CC002
SCSI selection or reselection
timeout occurred.
632CC010
Undefined sense key returned
by device.
632CC020
Configuration error.
632CC100
SCSI bus error occurred.
632CC110
SCSI command timeout
occurred.
632CC210
Informational system log entry
only.
632CC300
Media or device error
occurred.
632CC301
Media or device error
occurred.
632CC302
Media or device error
occurred.
632CC303
Media has an unknown
format.
632CC333
Incompatible media.
632CC400
Physical link error detected by
device.
632CC402
An internal program error
occurred.
632CCFF2
Informational system log entry
only.
632CCFF4
Internal device error occurred.
Action
Resolve any errors on the Network File System server.
Install any available operating system updates.
632Cyyyy codes are virtual optical SRCs
No corrective action is required.
Refer to the hosting partition for problem analysis.
Refer to the hosting partition for problem analysis.
Refer to the hosting partition for problem analysis.
Refer to the hosting partition for problem analysis.
Refer to the hosting partition for problem analysis.
No corrective action is required.
Refer to the hosting partition for problem analysis.
Refer to the hosting partition for problem analysis.
Refer to the hosting partition for problem analysis.
No corrective action is required.
1. Verify that the disk has a supported format.
2. If the format is supported, clean the disk and attempt the
failing operation again.
3. If the operation fails again with the same system reference code,
ask your media source for a replacement disk.
Refer to the hosting partition for problem analysis.
Install any available operating system updates.
No corrective action is required.
Refer to the hosting partition for problem analysis.
23