Table 12. B200xxxx Logical partition SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
B200 xxxx Error
Code
Description
3084
A problem occurred during the
startup of a partition.
The adapter type might not be
supported.
3088
Informational system log entry only.
308C
A problem occurred during the
startup of a partition.
The adapter type cannot be
determined.
3090
A problem occurred during the
startup of a partition.
3110
A problem occurred during the
startup of a partition.
3113
A problem occurred during the
startup of a partition.
3114
A problem occurred during the
startup of a partition.
3120
Informational system log entry only.
3123
Informational system log entry only.
3125
During the startup of a partition, the
blade server firmware could not
obtain a segment of main storage
within the blade server to use for
managing the creation of a partition.
3128
A problem occurred during the
startup of a partition. A return code
for an unexpected failure was
returned when attempting to query
the load source path.
3130
A problem occurred during the
startup of a partition.
3135
A problem occurred during the
startup of a partition.
3140
A problem occurred during the
startup of a partition. This is a
configuration problem in the
partition.
3141
Informational system log entry only.
3142
Informational system log entry only.
3143
Informational system log entry only.
3144
Informational system log entry only.
3145
Informational system log entry only.
Action
Verify that the adapter type is supported.
No corrective action is required.
Verify that a valid I/O Load Source is tagged.
Go to "Isolating firmware problems" on page 222.
Go to "Isolating firmware problems" on page 222.
Look for B7xx xxxx errors and resolve them.
Look for other errors and resolve them.
No corrective action is required.
No corrective action is required.
Check for server firmware updates; then, install the
updates if available.
Look for and resolve B700 69xx errors.
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
Reconfigure the partition to include the intended load
source path.
No corrective action is required.
No corrective action is required.
No corrective action is required.
No corrective action is required.
No corrective action is required.
33