Table 31. POWER Hypervisor isolation procedures (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Isolation
Symptom
Procedure Code
The failing
MEMDIMM
Symbolic CRU
component is one of
the memory DIMMs.
NEXTLVL
Contact IBM Support.
Symbolic CRU
PIOCARD
The hardware that
Symbolic CRU
controls PCI adapters
and PCI card slots
detected an error. The
direct select address
(DSA) portion of the
system reference code
(SRC) identifies the
location code of the
failing component.
204
JS12 Type 7998: Problem Determination and Service Guide
Action
1. Replace the failing CRU:
DIMM 1 (P1-C1)
Memory module 1
DIMM 2 (P1-C2)
Memory module 2
DIMM 3 (P1-C3)
Memory module 3
DIMM 4 (P1-C4)
Memory module 4
DIMM 5 (P1-C5)
Memory module 5
DIMM 6 (P1-C6)
Memory module 6
DIMM 7 (P1-C7)
Memory module 7
DIMM 8 (P1-C8)
Memory module 8
2. See "Removing a memory module" on page 251 for location
information and the removal procedure.
3. Install new memory DIMMs, as described in "Installing a memory
module" on page 251.
See "Supported DIMMs" on page 4 for more information.
1. Collect the error log information.
2. Get the DSA, which is word 7 of the associated B700xxxx SRC.
3. Use the hexadecimal value of the DSA to determine the location code
of the failing CRU.
v If the value is 05120010, the location code is P1-C10.
v If the value is xxxx 0100, the location code is P1-C11.