Table F-19. Routine 80 - Servo Diagnostic Error Codes - Fujitsu M2488 Product Manual

Hide thumbs Also See for M2488:
Table of Contents

Advertisement

M2488 PRODUCT GUIDE

Table F-19. Routine 80 - Servo Diagnostic Error Codes

ROUTINE
TEST
*
Servo Diagnostic Tests
0x80
0x80
0x01
Servo Diag: Logic test
0x80
0x02
Servo Diag: Photo sensors test
April 1997
ERROR
TITLE
CODE
0xE0
0xE1
0xE2
0x41
0x42
0x43
0x44
0x45
0x46
0x47
0x48
0xE3
0xE4
0xE5
0x02
0x03
0x04
0x05
0x06
0x07
0x08
CG00000-011503 REV. A
DIAGNOSTIC TESTS AND ERROR CODES
DESCRIPTION
Test initialization error, the controller could
not sense the presence of a DVL card. The
DTC card must be connected to a DVL card in
order to run this test.
Test initialization error, a servo unload com-
mand failed while attempting to eject a car-
tridge.
Servo reported error while attempting to
unload a cartridge during test initialization.
Dummy signal of the file reel tachometer is
wrong
GAP counter is wrong
RRC counter is wrong
Forward direction of the file reel tachometer is
wrong
Backward direction of the file reel tachometer
is wrong
Dummy signal of the machine reel tachometer
is wrong
Forward direction of the machine reel
tachometer is wrong
Backward direction of the machine reel
tachometer is wrong
Servo command was not accepted; sense
information was built
Servo command was accepted but failed to
complete within 60 seconds
Servo error occurred that was not reported as
a diagnostic error.
The tape path home sensor is off
The cartridge in sensor is on
The tape path "CT" sensor is off
The tape path "MR" sensor is on
The cartridge in sensor in on
The file protect sensor is off
The cleaning cartridge sensor is on
F-69