Table F-3. Routine 1 - Control Store Diagnostic Error Codes
ROUTINE
TEST
0x01
0x01
Control store data bus test
0x01
0x02
Control store byte boundary test
0x01
0x03
Control store half word boundary
test
0x01
0x04
Control store address bus test
0x01
0x05
Control store incrementing pattern
test
0x06
Control store data pattern AA test
0x01
0x01
0x07
Control store data pattern 55 test
0x01
0x08
Control store walking FFs test
April 1997
ERROR
TITLE
CODE
0x01
0x02
0x01
0x02
0x03
0x04
0x01
0x02
0x03
0x04
0x01
0x01
0x01
0x01
0x01
CG00000-011503 REV. A
DIAGNOSTIC TESTS AND ERROR CODES
DESCRIPTION
Data miscompare clearing control store
address 0
Data bus bit miscompare
Control store address 0 not set to
0xFFFFFFFF
Control store address 0x04 couldn't be set to 0
Read/verify of control store byte write failed
Read/verify of control store data word failed
Data miscompare clearing control store
address 0
Control store address 0x04 couldn't be set to
0xFFFFFFFF
Read/verify of control store half-word write
failed
Read/verify of control store data word failed
Read/verify of control store address bus bit
failed
Read/verify of control store incrementing pat-
tern failed
Control store data word miscompare
Control store data word miscompare
Control store data miscompare
F-7