M2488 PRODUCT GUIDE
5-1
INTRODUCTION
This chapter describes the parameters for the M2488. The following information is located in this chap-
ter:
5-2 ADDITIONAL COMMAND INFORMATION ON MTU MODE SELECT AND MODE
SENSE COMMANDS
5-3 MTU INQUIRY/CHANGE DEFINITION VITAL PRODUCT DATA PAGES
5-2
ADDITIONAL COMMAND INFORMATION ON MTU MODE SELECT AND
MODE SENSE COMMANDS
Table 5-1 lists the page codes supported by the MODE SELECT and MODE SENSE commands.
PAGE
CODE
00h
01h
02h
0Ah
10h
3Fh
The current value of non-changeable Mode Parameters must be
returned in MODE SELECT command data.
5-2.1
The Parameters Savable Bit (All pages)
When using the MODE SENSE command, a Parameters Savable (PS) bit of one indicates that the
mode page can be saved by the target in a non-volatile, vendor-specific location. A PS bit of zero
indicates that the supported parameters cannot be saved. When using the MODE SELECT command,
the PS bit is reserved.
April 1997
CHAPTER 5
TAPE UNIT PARAMETERS
Table 5-1. Page Codes
DESCRIPTION
Vendor Unique Parameters
Error Recovery and Reporting Parameters
Disconnect/Reconnect Control Parameters
Common Device-Type Control Parameters
Device Configuration Parameters
(MODE SENSE ONLY) Target returns all supported pages. The pages are
returned in the MODE SENSE data in the following order:
Page 01h, page 02h, page 0Ah, page 10h, page 00h.
** NOTE **
CG00000-011503 REV. A
TAPE UNIT PARAMETERS
5-1