DIAGNOSTIC TESTS AND ERROR CODES
Table F-19. Routine 80 - Servo Diagnostic Error Codes (Continued)
ROUTINE
TEST
0x02
Servo Diag: Photo sensors test
0x80
0x80
0x03
Servo Diag: Loader test
0x80
0x04
Servo Diag: Threader test
0x80
0x05
Servo Diag: Tachometer test
F-70
ERROR
TITLE
CODE
0x09
0xE3
0xE4
0xE5
0x01
0x02
0x03
0x04
0xE3
0xE4
0xE5
0x01
0x02
0x03
0x04
0xE3
0xE4
0xE5
0x01
0x02
0x03
0x04
0x05
CG00000-011503 REV. A
M2488 PRODUCT GUIDE
DESCRIPTION
The cartridge mount sensor is on
Servo command was not accepted; sense
information was built
Servo command was accepted but failed to
complete within 60 seconds
Servo error occurred that was not reported as
a diagnostic error.
Loader downward motion is too slow
Loader downward motion is too fast
Loader upward motion is too slow
Loader upward motion is too fast
Servo command was not accepted; sense
information was built
Servo command was accepted but failed to
complete within 60 seconds
Servo error occurred that was not reported as
a diagnostic error.
Threader forward motion is too slow
Threader forward motion is too fast
Threader backward motion is too slow
Threader backward motion is too fast
Servo command was not accepted; sense
information was built
Servo command was accepted but failed to
complete within 60 seconds
Servo error occurred that was not reported as
a diagnostic error.
The machine reel tachometer "A" is always
"1"
The machine reel tachometer "A" is always
"0"
The machine reel tachometer "B" is always
"1"
The machine reel tachometer "B" is always
"0"
The machine reel tachometer "A" and "B"
changed at the same time