Unloading - Fujitsu M2488 Product Manual

Hide thumbs Also See for M2488:
Table of Contents

Advertisement

M2488 PRODUCT GUIDE
The tests can be set using the following parameters:
DIAG parameter 1: For "FRD READ", "BWD READ" or "WRITE", set the operation mode.
DIAG parameter 2: For "FWD READ", "BWD READ", "WRITE", "FRD/BRD", "L.W.R." and "FEED
DIAG parameter 4: For "WRITE", select a write data pattern from the following:
DIAG parameter 5: For "L.W.R.", select a path of the Loop Write To Read command from the following:
DIAG parameter 6: For "L.W.R.", set a level of the Loop Write To Read command from the following:
execution time: When diag parameter 1 is START/STOP, set the GO ON time (time when the tape is
stop time: When diag parameter 1 is START/STOP, set the GO OFF time (time when the tape is
execute count: Specify an execution count. Specify a command execution count from 1 to 99,999.
H-4.3.2
LOAD/UNLOAD: Two diagnostic tests to check loading and unloading
(Set the tests in detail using the given parameters.)
1)
NO CTG
2)
WITH CTG
The tests can be set using the following parameters:
DIAG parameter 2: For NO CTG, select a test type from the following:
DIAG parameter 3: For WITH CTG, select a loading position from the following:
April 1997
0x00 - STREAMING : Set a continuous read (or write) operation.
0x01 - START/STOP : Set the start/stop operation.
: For "LOCATE", specify a sector. Specify a location sector from 1 to 99.
THR", specify a test wrap.
0x00 - WRAP 1
: Wrap-1 test
0x01 - WRAP 2
: Wrap-2 test
0x00 - D.S.E. PT
: D.S.E. pattern
0x01 - 2 F PT
: 2F pattern
0x02 - 1/6 F PT
: 1/6F pattern
0x03 - 1/5 F PT
: 1/5F pattern
0x04 - 1/4 F PT
: 1/4F pattern
0x05 - 1/3 F PT
: 1/3F pattern
0x06 - 1/2 F PT
: 1/2F pattern
0x07 - 1 F PT
: 1F pattern
0x08 - 1/12 F PT
: 1/12F pattern
0x09 - 1.5 F PT
: 1.5F pattern
0x00 - PATH:A
: Path A
0x01 - PATH:B
: Path B
0x00 - LEVEL LO
: Low level
0x01 - LEVEL HI
: High level
running).1 count is 10msec.
If this parameter is set to "0," the GO ON time becomes 10 ms.
: For the path test, specifies start position by the machine reel counter.
not running). 1 count is 10msec.
If this parameter is set to "0," the GO OFF time becomes 0 ms.
: For the path test, specifies end position by the machine reel counter.
When 0 is set, the command execution continues with no stop.
Loader and Threader test not using cartridge
:
: Loader and Threader test using cartridge.
0x00 - LOADER
: Loader test
0x01 - THREADER
: Threader test.
CG00000-011503 REV. A
MTU DIAGNOSTIC SPECIFICATIONS
------- CMD CD : 0x
------- CMD CD : 0x
20
21
H-5