Table F-10. Routine 8 - Formatter Counters Diagnostic Error Codes - Fujitsu M2488 Product Manual

Hide thumbs Also See for M2488:
Table of Contents

Advertisement

DIAGNOSTIC TESTS AND ERROR CODES
Table F-9. Routine 7 - SCSI Protocol Controller Diagnostic Error Codes (Continued)
ROUTINE
TEST
0x05
SPC MPU bus parity test
0x07

Table F-10. Routine 8 - Formatter Counters Diagnostic Error Codes

ROUTINE
TEST
0x08
0x01
Formatter Counter 0 test
F-22
ERROR
TITLE
CODE
0x08
0x09
0x0A
ERROR
TITLE
CODE
0x01
0x02
0x03
0x04
0x05
0x06
0x07
0x08
0x09
CG00000-011503 REV. A
M2488 PRODUCT GUIDE
DESCRIPTION
The SPC interrupt request could not be
cleared
CP bus parity error was not reported as
expected
Unexpected Check 1 condition was reported
after attempting to clear the Check 1 CP bus
parity error
DESCRIPTION
The Formatter Counter 0 count enable register
could not be cleared
A data miscompare occurred walking a one
through the Formatter Counter 0 high byte
count register
A data miscompare occurred walking a one
through the Formatter Counter 0 low byte
count register
Test Jump Carry Out bit for the high byte
count of Formatter Counter 0 was set prema-
turely before counter was started
An unexpected value was read in the count
enable register for Formatter Counter 0 after
the high byte counter finished running
The high byte count for Formatter Counter 0
did not contain the expected value after the
counter finished running
Test Jump Carry Out bit for the high byte
count of Formatter Counter 0 was not set as
expected after the counter finished running
Test Jump Carry Out bit for the low byte
count of Formatter Counter 0 was set prema-
turely before counter was started
An unexpected value was read in the count
enable register for Formatter Counter 0 after
the low byte counter finished running
April 1997