Table 8-20. Page Code 80H Test Description - Fujitsu M2488 Product Manual

Hide thumbs Also See for M2488:
Table of Contents

Advertisement

MAINTENANCE AND SERVICING
b. Page Code 80h Tests
ONLINE
TEST
ROUTINE
Self Test
01h
Loop Write/
50h
Read LVL1 -
Digital Tests
Loop Write/
51h
Read LVL2 -
Analog Tests
Write Data Tests
52h
Read Date Tests
53h
Combination
54h
Tests 1
Combination
57h
Tests 2
Medium
C0h
Changer - No
Cartridge
Present
Medium
C2h
Changer - No
Magazine Set
8-26

Table 8-20. Page Code 80h Test Description

DESCRIPTION
The same tests as described in Table 8-19. The
self test is also SCSI Routine 01h.
Data is written into the data buffer and passed
from the data buffer to the MTU. The MTU
returns the data to the formatter through both the
analog and digital check circuitry. No tape motion
is required.
Data is written into the data buffer and passed
from the data buffer through the formatter. No
tape motion is required.
Tape is positioned at Load Point and 4 tones are
written. They are each 4 meters in length and
written with the order of Erase Tone, IBG Tone,
Tape Mark (TM) Tone, and Density ID (DID)
Tone.
Tape is positioned at Load Point and 4 meters of
Erase Tone, IBG Tone, TM Tone and DID Tone
are written. The tones are read back in reverse
direction and a rewind is performed.
Tape is positioned at Load Point and 4 tones of 4
meters each is written. The tones are; Erase Tone,
IBG Tone, TM Tone and DID Tone. The tape is
then rewound. At Load Point, another 4 tones are
written (same as above), but this time instead of
just rewinding, the tones are read in the reverse
direction.
An 'all zeroes' data pattern is replicated in the
data buffer and blocks are written to tape until
Logical EOM is detected. The first block written
is 255 bytes in length. Each succeeding block
length is incremented by one. All data is read in
both the forward and reverse directions.
Tests the drive logic, photo sensors, loader mech-
anism, and the tachometer pulse generation.
Tests the ACL/FACL loader mechanism and
photo sensors.
CG00000-011503 REV. A
M2488 PRODUCT GUIDE
OPERATOR
INTERVENTION
A scratch tape must be loaded
prior to running this Online
routine.
A scratch tape must be loaded
prior to running this Online
routine.
A scratch tape must be loaded
prior to running this Online
routine.
A scratch tape must be loaded
prior to running this Online
routine.
Before running this diagnostic,
the xCL magazine must be
removed.
Before running this diagnostic,
the xCL magazine must be
removed.
For a FACL, after this diagnos-
tic has been requested, the
TEST button on the FACL
operator panel must be pressed
for this diagnostic to begin.
April 1997

Hide quick links:

Advertisement

Table of Contents
loading