Table F-14. Routine 12 - Edrc Address Bus Diagnostic Error Codes - Fujitsu M2488 Product Manual

Hide thumbs Also See for M2488:
Table of Contents

Advertisement

DIAGNOSTIC TESTS AND ERROR CODES

Table F-14. Routine 12 - EDRC Address Bus Diagnostic Error Codes

ROUTINE
TEST
*
All R20 Address Check Diagnos-
0x12
tics
0x12
0x01
SDDP-R20 buffer flush signal
test, mode 14h
F-38
ERROR
TITLE
CODE
0xD0
0xE0
0xE1
0xE2
0xE3
0xE4
0xE5
0xE6
0xE7
0xE8
0xE9
0x10
0x11
0x12
0x13
0x14
0xEF
0x01
0x02
CG00000-011503 REV. A
M2488 PRODUCT GUIDE
DESCRIPTION
SPC register initialization failed
SPC did not generate an interrupt request
SPC interrupt was not detected at the Interrupt
Request Controller
The SPC interrupt was cleared while clearing
the Interrupt Request Controller.
SPC interrupt/step code did not report Com-
mand Complete
The SPC interrupt request could not be
cleared
SPC did not generate an interrupt request
SPC interrupt was not detected at the Interrupt
Request Controller
The SPC interrupt was cleared while clearing
the Interrupt Request Controller.
SPC interrupt/step code did not report Diag-
nostic Self-Test passed
The SPC interrupt request could not be
cleared
At end of test, SPC did not generate an inter-
rupt request.
At end of test, SPC interrupt was not detected
at the Interrupt Request Controller.
At end of test, the SPC interrupt was cleared
while clearing the Interrupt Request Control-
ler.
At end of test, SPC interrupt/step code did not
report Command Complete.
At end of test, the SPC interrupt request could
not be cleared.
SPC interrupt request or interrupt/step register
could not be cleared at the end of the test
after a write diag operation was initialized in
the spc chip, the SPC-status register did not
have one of the following:
SPC_data_trans_rdy, SPC_busy, or
SPC_data_reg_empty.
A non SUCCESS status was returned from
the function call rm_request_wrtbuffer.