Table F-19. Routine 80 - Servo Diagnostic Error Codes (Continued)
ROUTINE
TEST
0x05
Servo Diag: Tachometer test
0x80
0x80
0x06
Servo Diag: ACL/FACL test
0x80
0x07
Servo Diag: Manual Sensor test
0x80
0x08
Servo Diag: Manual ACL test
April 1997
ERROR
TITLE
CODE
0x06
0x08
0x0A
0x0D
0xE3
0xE4
0xE5
0x01
0xE3
0xE4
0xE5
0x80
0xE3
0x01
0xE3
CG00000-011503 REV. A
DIAGNOSTIC TESTS AND ERROR CODES
DESCRIPTION
The machine reel turns too slow
File reel tachometer phase error in forward
direction
File reel tachometer phase error in backward
direction
File reel turns too slow
Servo command was not accepted; sense
information was built
Servo command was accepted but failed to
complete within 60 seconds
Servo error occurred that was not reported as
a diagnostic error.
The servo command completed in error and
valid sense information was built. Byte 19 of
the sense information, which can be found in
Table (ACL) or Table (FACL), gives a more
detailed description of the error.
Medium changer not detected; this test cannot
be run without a medium changer attached.
Magazine eject failed.
Servo reported error occurred during ACL/
FACL test initialization.
Servo error reported during Manual Sensor
test execution.
Medium changer not detected; this test cannot
be run without a medium changer attached.
Servo error reported during Manual ACL test
execution.
Medium changer not detected; this test cannot
be run without a medium changer attached.
F-71