4-3.28.5 Send Diagnostic Sense Keys - Fujitsu M2488 Product Manual

Hide thumbs Also See for M2488:
Table of Contents

Advertisement

TAPE UNIT SCSI COMMANDS
4-3.28.5
SEND DIAGNOSTIC Sense Keys
One of the following sense keys may be returned if a CHECK CONDITION was indicated:
SENSE KEY
CONDITION
1h
RECOVERED ERROR
3h
MEDIUM ERROR
4h
HARDWARE ERROR
5h
ILLEGAL REQUEST
6h
UNIT ATTENTION
Bh
ABORTED COMMAND
Dh
VOLUME OVERFLOW
4-134
DESCRIPTION
Recovery was performed when writing buffered data before the buff-
ered mode operation occurred in SEND DIAGNOSTIC command.
1. Write of buffered data failed due to defective tape.
2. An attempt was made to write 36-track data on 18-track formatted
medium.
1. SCSI interface error occurred due to hardware failure (e.g. transfer
of SEND DIAGNOSTIC data failed due to hardware failure).
2. Write of buffered data failed due to a hardware failure.
3. The self-test is not successful in SEND DIAGNOSTIC command.
1. Reserved bit was found set in the CDB of the SEND DIAGNOS-
TIC command.
2. Flag bit in the SEND DIAGNOSTIC CDB was set and Link bit
was not set.
3. There is a parameter list error.
Indicates the SEND DIAGNOSTIC command was not performed
due to one of the following:
1. The tape cartridge may have been changed.
2. The target has been reset.
3. The Mode parameters have been changed by another initiator.
4. The version of the microcode has been changed (microcode down-
loaded).
5. A cartridge was loaded with a tape length that is too long or too
short.
SEND DIAGNOSTIC command was aborted.
Write of buffered data prior to the SEND DIAGNOSTIC operation
failed because physical End-of-Tape has been reached.
CG00000-011503 REV. A
M2488 PRODUCT GUIDE
April 1997