Fujitsu M2488 Product Manual page 453

Hide thumbs Also See for M2488:
Table of Contents

Advertisement

M2488 PRODUCT GUIDE
Table F-16. Routine 20 - Loop Write to Read Diagnostic Error Codes (Continued)
ROUTINE
TEST
0x03
LWR0 - EDRC Data - 36 track
0x20
0x20
0x04
Loop Write to Read 2 test - 36
track
April 1997
ERROR
TITLE
CODE
0xBD
0xBE
0xBF
0xC0
0xC1
0xC2
0xC3
0x20
0x21
0x22
0x23
0x24
0x25
0x26
0x27
0x28
0x29
0x2A
0x2B
0x2C
0x2D
0x2E
0x2F
CG00000-011503 REV. A
DIAGNOSTIC TESTS AND ERROR CODES
DESCRIPTION
PF_EOD Xreg - expected data not equal to
received data
PF_EODSEC Xreg - expected data not equal
to received data
PF_EOD_ID Xreg - expected data not equal
to received data
PF22_25 Xreg - expected data not equal to
received data
PF26_29 Xreg - expected data not equal to
received data
MOD_32 Xreg - expected data not equal to
received data
HRL Xreg - expected data not equal to
received data
RSVP failed to Respond
DATA Xreg Miscompare - RSVP not Ready
DATB Xreg Miscompare - RSVP not Ready
FHC1 time-out - DBOB not detected by
RSVP
FLC0 time-out - RSVP detected Long IBG
FHC2 or FLC2 Time Out - Slow End of Data
Block
Lost DBOB prior to PHOK or while waiting
for DPOST
PHOK not seen in time
Time-out waiting for DPRE
Lost DBOB waiting for DPRE
Time-out waiting for DPOST
PHOK on after Read End
RSVP Dead Man time-out
Last Blk not Found
RSVP error - RSVP failed, cause unknown
IBG active, should not be - check INLWR
pulled high.
F-53