Table 4-120. Page 81H - Manufacturing Online Diagnostic Test Page; Table 4-121. Page Code 81H Field Description - Fujitsu M2488 Product Manual

Hide thumbs Also See for M2488:
Table of Contents

Advertisement

M2488 PRODUCT GUIDE
Description of Page Code 81h
This page allows user selection of Manufacturing Online Diagnostic Routines and control over the
number of times each routine is to be executed.

Table 4-120. Page 81h - Manufacturing Online Diagnostic Test Page

BYTES
7
0
1
2-3
4
5
6
7
8
9-11
12-13
14-15
16-19
20-23
24-27
28-33
Description of fields in Page Code 81h
BYTE
BIT
VALUE
0
0-7
4
0-7
5
0-7
April 1997
6
5
4
Page code (81h)
Reserved (All bits are set to zero)
Page Length (001Eh)
Manufacturing Routine number
Execute Count
EDRC Compression Mode
Block Delay (ms)
Block Length (KB)
Block Count
Block Data Pattern
Data Pattern Increment
Block Number
Space Count
Write Filemark Count
Reserved (All bits are set to zero)

Table 4-121. Page Code 81h Field Description

81h
Page Code for Manufacturing Online Diagnostics.
Manufacturing Routine number (refer to Chapter 8 for a list of Manufacturing rou-
tines).
Execute Count. The number of times to repeat the Manufacturing Online Diagnostic
Routine. A value of 0 indicates that the diagnostic will repeat until one of the follow-
ing conditions is met: a SCSI BUS RESET is issued, the initiator ABORTS this com-
mand, or a failure is detected during the execution of the Manufacturing Online
Diagnostic.
CG00000-011503 REV. A
TAPE UNIT SCSI COMMANDS
BITS
3
2
1
DESCRIPTION
0
4-129

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents