DIAGNOSTIC TESTS AND ERROR CODES
Table F-5. Routine 3 - CP Bus Parity Diagnostic Error Codes (Continued)
ROUTINE
TEST
0x03
CP Bus parity - SPC
0x03
F-12
ERROR
TITLE
CODE
0x04
0x05
0x06
0x07
0x10
0x20
0x21
0x22
0x23
0x24
0x30
0x31
0x32
0x33
0x34
0x40
0x41
0x42
CG00000-011503 REV. A
M2488 PRODUCT GUIDE
DESCRIPTION
An unexpected Check 1 condition was pend-
ing after an attempt to clear it was made
An expected CP bus parity was not detected
after attempting to read an SPC register with
SPC parity inverted
An unexpected Check 1 condition was pend-
ing after an attempt to clear it was made
An unexpected Check 1 condition was
detected
Initialization of the SPC chip failed
SPC interrupt request was not generated dur-
ing SPC Diagnostic initialization
An SPC interrupt was not detected in the
Interrupt Request Controller (IRC) during
SPC Diagnostic initialization
The SPC interrupt was inadvertently cleared
when the Interrupt Request Controller was
cleared
The SPC interrupt/step code did not report
command complete as expected
The SPC interrupt request could not be
cleared
An SPC interrupt request was not generated
by the SPC during diagnostic test
An SPC interrupt was not detected in the
Interrupt Request Controller (IRC) during
SPC Diagnostic initialization
The SPC interrupt was inadvertently cleared
when the Interrupt Request Controller was
cleared
The SPC interrupt/step code did not report a
Register Parity error as expected
The SPC interrupt request could not be
cleared
An SPC interrupt request was not generated
by the SPC during diagnostic test
An expected SPC interrupt was not detected
in the Interrupt Request Controller (IRC)
The SPC interrupt was inadvertently cleared
when the Interrupt Request Controller was
cleared