H-4 Mtu Diag Parameter - Fujitsu M2488 Product Manual

Hide thumbs Also See for M2488:
Table of Contents

Advertisement

M2488 PRODUCT GUIDE
COMBINATION test
Combination test
H-4
MTU DIAG PARAMETER
H-4.1
DIAG activation parameter
The total data requirement for the MTU DIAG activation is 480 bytes.
H-4.2
Explanation
The parameter for the DIAG activation is composed of 16 groups. Each group requires 30 bytes.
After the DIAG test of group 1 has been completed, the test of group 2 is executed and so on. If data
0xff or 0x0C is specified for the DIAG command code, the DIAGs of subsequent groups are not exe-
cuted and all DIAGs are terminated. If an error is detected during a DIAG execution, that test is ter-
minated.
struct diag parm {
DIAG command code:
Specifies the command code of the DIAG to be executed.
DIAG parameter 1 to 9:
Selects the mode according to the DIAG to be executed.
April 1997
FWD READ
BWD READ
WRITE
D.S.E
LOCATE
REWIND
LOAD
UNLOAD
EJECT
TP PATH
REPEAT
RUNNING
ERROR RESET
unsigned char diag command;
unsigned char diag parameter [9];
unsigned long execute time;
unsigned long stop time;
unsigned long execute count;
unsigned char reserve [8]
} diag input parm [16];
diag_parameter 1
------
------
diag_parameter 2
------
------
CG00000-011503 REV. A
MTU DIAGNOSTIC SPECIFICATIONS
Forward read test
BACKWARD READ test.
Write test.
D.S.E.test
Locating
Rewinding to wrap1-BOT
Load
Unload
Eject
tape path test
Set next execution group and
repeat counter.
END TEST.
For the read/write DIAG, set the operation mode.
For the locate DIAG, specify a sector.
For the read/write DIAG, specify a test wrap.
For the load/unload DIAG, specify "LOADER" or
"THREADER".
CMD CD : 0x01
CMD CD : 0x02
CMD CD : 0x03
CMD CD : 0x04
CMD CD : 0x05
CMD CD : 0x06
CMD CD : 0x07
CMD CD : 0x08
CMD CD : 0x80
CMD CD : 0x0B
CMD CD : 0x0A
CMD CD : 0x0C or 0xFF
CMD CD : 0x70 or 0xF0
H-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents