TAPE UNIT SCSI COMMANDS
Description of the Page Code 80h
BYTES
7
0
1
2-3
4
5
6-7
8-9
10-11
12-19
BYTE
BIT
VALUE
4
0-7
5
0-7
6-11
4-86

Table 4-80. Page 80h - Online Diagnostic Test Page

6
5
4
Page Code (80h)
Page Length (0010h)
Routine in error (Routine number)
Execute Count (Pass Count)
First Fault Symptom Code
Second Fault Symptom Code
Third Fault Symptom Code

Table 4-81. Page 80h Field Description

The Routine in Error field contains the Routine ID of the failing routine. If this
field contains 00h, no errors were detected during the last execution of a SEND
DIAGNOSTIC command.
The Execute Count field contains the number of passes attempted before an error
was detected. If an error is detected on the first pass, this field contains a 1. This
field is reset each time a new (different) routine is started. For example: if the
SEND DIAGNOSTIC command Parameter list contained a pass count of 4 for
Routine 50, and a pass count of 7 for Routine 51, and an error was detected on
the third attempt to execute Routine 51, this field would contain a 3.
This field contains the Fault Symptom Codes that indicate the cause of the error.