Tape Library Error Codes; Example Error Code; Error Code Table; Table 4.1 Error Code Table - Fujitsu P3AM-5382-03ENZ0 Installing, Starting Up And Maintaining

Eternus lt20 s2 lto library
Table of Contents

Advertisement

Chapter 4 Troubleshooting

4.6 Tape Library Error Codes

4.6
Tape Library Error Codes
If an error occurs during operation of the library, the library stops the current operation and displays an
error code on the LCD screen. Unless otherwise noted in
to the library and retrying the last operation. If the error persists, contact support personnel.
4.6.1

Example Error Code

EVENT -6
A5 F1
Where:
Sequence number -6 indicates the position in sequence list, 0 being the most recent.
Log shows a load error (code A5 = fan error, sub code F1 = caused by the fan at the back connector plate).
The event log with the library also includes a date stamp for each event. Press Enter to display the associated
timestamp in the following format:
ddd:hh:mm:ss:HH
where:
ddd
days
hh
hours
mm
minutes
ss
seconds
HH
1/100 second
A description of each error code and possible solution is provided in the following table.
4.6.2

Error Code Table

Table 4.1
Error code table
Error Code
80
81
82
83
84
85
86
FUJITSU Storage ETERNUS LT20 S2 LTO Library Installing, Starting Up and Maintaining
Description
Barcode Reader Error, cannot initialize BCR
Barcode Reader Error, no response from BCR
EEPROM Error, no response from EEPROM
(located on robot controller)
Robot controller generic problem
Setting of gripper motor parameters failed
Setting of slider motor parameters failed
Setting of elevator motor parameters failed
Copyright 2014 FUJITSU LIMITED
Table
4.1, try to resolve the error by cycling power
Retry operation; after several occurrences contact
technical support
Retry operation; after several occurrences contact
technical support
Retry operation; after several occurrences contact
technical support
Reset the unit and retry operation. After several
occurrences contact technical support
Reset the unit and retry operation. After several
occurrences contact technical support
Reset the unit and retry operation. After several
occurrences contact technical support
Reset the unit and retry operation. After several
occurrences contact technical support
76
User Action
P3AM-5382-03ENZ0