Table 5.29 Error Recovery Control - Fujitsu MHV2200BT Product Manual

Table of Contents

Advertisement

Byte
Name
014h
to
Pattern
017h
018h
to
(Reserved)
1FFh
* It is invalid excluding the description value.
Byte
Name
000h
Action Code
001h
002h
Function Code
003h
004h
Selection Code
005h
006h
Value
007h
008h
to
(Reserved)
1FFh
* It is invalid excluding the description value.
C141-E244
Table 5.28 LBA SEGMENT ACCESS (2/2)
Value
It specifies it for Function Code=0001h for data pattern
(4 byte)
of 32bit.
-
Reserved

Table 5.29 ERROR RECOVERY CONTROL

Value
0003h
ERROR RECOVERY CONTROL
Set New Value
0001h
The retry processing when making an error in the
specified timer
Return Current Value
0002h
The timer value of the error recovery being set now is
displayed in SN /SC field.
0001h
Read Timer
0002h
Write Timer
Set to Timer Value (x 100 ms)
Minimum value is 10 sec.
(ex.) 0000h: Disable timeout
(2 byte)
-
Reserved
5.3 Host Commands
Description
Description
0063h: Invalid
0064h: 10000 ms (10 s)
5-79