Table F-9. Routine 7 - SCSI Protocol Controller Diagnostic Error Codes (Continued)
ROUTINE
TEST
0x04
SPC to Data Buffer DMA test
0x07
0x07
0x05
SPC MPU bus parity test
April 1997
ERROR
TITLE
CODE
0x09
0x0A
0x0B
0x0C
0x10
0x11
0x12
0x13
0x14
0x20
0x21
0x22
0x23
0x24
0x01
0x02
0x03
0x04
0x05
0x06
0x07
CG00000-011503 REV. A
DIAGNOSTIC TESTS AND ERROR CODES
DESCRIPTION
Incorrect SCSI bus status during diagnostic
data transfer while expecting REQ de-asser-
tion
SPC reported an incorrect data transfer length
Record/Buffer manager did not report suc-
cessful completion for the DMA transfer
Data miscompare detected in SPC MSC
buffer after DMA data transfer completed
SPC did not generate an interrupt request
SPC interrupt was not detected at the Interrupt
Request Controller
The SPC interrupt was cleared while clearing
the Interrupt Request Controller.
An incorrect SPC interrupt/step code was
reported
The SPC interrupt request could not be
cleared
SPC did not generate an interrupt request
SPC interrupt was not detected at the Interrupt
Request Controller
The SPC interrupt was cleared while clearing
the Interrupt Request Controller.
SPC interrupt/step code did not report Com-
mand Complete
The SPC interrupt request could not be
cleared
SPC reported incorrect status
Bad SCSI bus status detected waiting for REQ
assertion during diagnostic data transfer
Incorrect SCSI bus status during diagnostic
data transfer while expecting REQ de-asser-
tion
SPC did not generate an interrupt request
SPC interrupt was not detected at the Interrupt
Request Controller
The SPC interrupt was cleared while clearing
the Interrupt Request Controller.
SPC interrupt/step code did not report MPU
Parity Error as expected