Fujitsu M2488 Product Manual page 384

Hide thumbs Also See for M2488:
Table of Contents

Advertisement

FAULT SYMPTOM CODES
F.S.C. #
9009
4 Meter Tones - 18 Track DID tone dropout
900A
4 Meter Tones - Too many total tone dropouts
900B
4 Meter Tones - Too many continuous tone dropouts
900C
4 Meter Tones - Continuous ERG tone not met
900D
4 Meter Tones - Continuous IBG tone not met
900E
4 Meter Tones - Continuous TM tone not met
900F
4 Meter Tones - Continuous 18 Track DID tone not met
9010
4 Meter Tones - Total not met on Wrap Mark
9011
4 Meter Tones - Continues not met on Wrap Mark
9012
4 Meter Tones - Continues not met on 36 Track DID
9013
4 Meter Tones - Total not met on 36 Track DID
9061
Too many total drops on Read DID
9062
Continuous not met on Read DID
Continuous not met on Read TM
9063
9064
DID too long on Read
9180
Hardware error on readback at end of IBG
9181
DBOB off between HBOB and DPRE
9182
DPRE time-out after PHOK on
9183
DBOB off before DPOST is detected
9184
RDEND on before DPOST is detected
9185
RDEND time-out after DPOST is detected
9188
Long IBG detected
918A
RECA dropped at DID write
918B
Can't set RECA at DID write
918C
Dropout detected at IDS write
918D
Dropout detected at IBG after IDS write
918E
Misposition by servo, started too late into IBG
918F
Misposition by servo, started over previous block or mark
9190
Can't detect regular DTM length
9191
Can't detect regular length IBG after DTM
D-4
Table D-2. Formatter Error Recovery (Continued)
DESCRIPTION
CG00000-011503 REV. A
M2488 PRODUCT GUIDE
BYTES
E.R.P.A.
29-39
GROUP
23/25
04
23/25
04
23/25
04
23/25
04
23/25
04
23/25
04
23/25
04
23/25
04
23/25
04
23/25
04
23/25
04
23
01
23
01
23
01
23
01
25
04
25
04
25
04
25
04
25
04
25
04
25
04
28
04
28
04
28
04
25
04
23
04
23
04
25
04
25
04