ERPA CODES
ERPA
DESCRIPTION
CODE
Drive Equipment
35
Check
36
End-of-Data
Detected on Read
37
Tape Length Error
38
Physical End of Tape
39
Backward at BOT
3B
Volume Removed by
Operator
41
Block ID Sequence
Error
43
Intervention Required A CDB was issued to a drive that is not ready.
44
Locate Block Unsuc-
cessful
47
Control Unit Error
49
Bus Out Parity
4A
Control Unit ERP
Failed
4C
Recovered Hardware
Error
5B
Tape Extension Error
5C
Medium Changer
Command
5D
Tape Length Error
5E
Compaction Algo-
rithm Incompatible
6F
No Cartridge
77
Reel Diameter
Greater than ECCST
C-2
Table C-1. ERPA Codes (Continued)
One of the following has occurred:
1. The control unit cannot recover from a drive-detected error.
2. A check code message is displayed on the drive message display.
3. The automatic cartridge loader does not respond across the interconnection to the
tape drive.
4. A failure occurred during an index/load or unload cycle. The tape cartridge is not
manually retrievable by the operator.
An End-of-Data (EOD) mark was detected on the tape during a read operation.
The tape length in the cartridge is too short. The error could occur when the leader
block is replaced (the length of tape ahead of the BOT has been trimmed).
A read or write operation was in process when the physical end-of-tape was reached.
The drive does not pull the tape out of the cartridge.
While the tape was moving backwards, the beginning of tape was reached.
The Rewind Unload switch on the drive has been activated and the cartridge is
unloaded.
The control unit detected an incorrect Block ID sequence.
The control unit cannot find the block preceding the desired block.
The SCSI error processing microcode received an unrecognized ERPA code. Process-
ing continues.
The bus out parity error was detected on the command or parameter transfer.
The control unit could not recover from a data handling failure.
The control unit recovered from a hardware error.
An attempt was made to write 36-Track format data on 18-Track formatted medium.
A Medium Changer command was given to a device that does not have the Medium
Changer feature.
The tape length in the cartridge is too long.
An attempt was made to read an unsupported data compaction algorithm.
No cartridge at selected location; or selected location not within the magazine size; or
no magazine was present when an attempt was made to load a cartridge from the mag-
azine.