H-4.3.3 Acl Test: Two Diagnostic Tests To Check The Autoloader - Fujitsu M2488 Product Manual

Hide thumbs Also See for M2488:
Table of Contents

Advertisement

MTU DIAGNOSTIC SPECIFICATIONS
DIAG parameter 4: For WITH CTG only, select an unloading position from the following:
execute count: Specify an execution count. Specify a command execution count from 1 to 99,999.
H-4.3.3
ACL TEST: Two diagnostic tests to check the autoloader
(Set the tests in detail using the given parameters.)
1)
ACL LDUL
2)
MAG UPDW
The tests can be set using the following parameters:
DIAG parameter 3: For MAGAZINE UP/DOWN test, set the following:
DIAG parameter 4: For MAGAZINE UP/DOWN test, set the following:
execution time: For ACL LOAD/UNLOAD test, set the frequency in use of cleaning cartridge. Cleaning
execute count: Specify an execution count. Specify a command execution count from 1 to 99,999.
H-4.3.4
TESTMODE: Diagnostic test to measure operations
(This test has no parameter.)
1)
M1:LOAD
2)
M2:TPPFM
3)
M3:AC/PS:
4)
M4:MODCH: Measure the mode change time.
5)
M5:LOCAT:
6)
M6:REWND: Measure the tape rewinding time.
7)
M7:D.S.E:
8)
M8:UNLD:
9)
M9:CLEAN:
H-6
0x00 - S:LD HM
: Start loading from the loader home position.
0x01 - S:CTG IN
: Start loading from the cartridge-in position.
0x02 -
S:CAR DW
: Start loading from the carrier-down position.
0x00 - E:TH END
: Start unloading from the thread end.
0x01 - E:CAR DW
: Start unloading from the carrier-down position.
0x02 - 1/6 F PT
: Start unloading from the cartridge-in position.
When 0 is set, the command execution continues with no stop.
: Load and unload cartridges sequentially from the top posi-
tion of the magazine.
: Move the magazine between two position.
0xXX- STRT Position
0xXX- END Position
cartridge in cleaning cell is loaded every setting counter. (from 1 to 99,999) Only FACL.
If DIAG command code is set "0x90" and execution time is set "999", cleaning cartridge
is loaded one time.
When 0 is set, the command execution continues with no stop.
Measure the cartridge loading time
:
: Measure the tape acceleration/deceleration time.
Measure the tape access/positioning time.
Measure the tape locating time.
Measure the DSE time.
Measure the cartridge unloading time.
Measure the cleaning time.
CG00000-011503 REV. A
: Magazine up-down start position
ACL type:
0x00 - 0x09 (10 slot type)
0x00 - 0x04 (5 slot type)
FACL type:
0x00 - 0x06
: Magazine up-down end position.
ACL type:
0x00 - 0x09 (10 slot type)
0x00 - 0x04 (5 slot type)
FACL type:
0x00 - 0x06
M2488 PRODUCT GUIDE
------- CMD CD : 0x
90
------- CMD CD : 0x
91
------- CMD CD : 0x41
------- CMD CD : 0x
42
------- CMD CD : 0x43
------- CMD CD : 0x44
------- CMD CD : 0x45
------- CMD CD : 0x46
------- CMD CD : 0x47
------- CMD CD : 0x48
------- CMD CD : 0x49