Fujitsu M2488 Product Manual page 385

Hide thumbs Also See for M2488:
Table of Contents

Advertisement

M2488 PRODUCT GUIDE
F.S.C. #
Drop-out length over after DTM and IBG
9192
9194
Can't detect regular DERS length
9196
BOB or DTM length over after DERS and IBG ???
9198
DBOB off after BOB detected
919A
Abnormal TM format (No continuous)
919B
Abnormal ERS format
91B0
Can't detect regular WRAP length
91BA
Write Wrap Marks failed
92xx
Detect SRCK after DPRE : xx =
Bit 0 - Uncorrectable error
Bit 1 - Multiple track error
Bit 2 - Skew error
Bit 3 - Drop out error
Bit 4 - CRC error
Bit 5 - Postamble error
Bit 6 - Start read check
Bit 7 - End of data check
(Bit 0 = MSB, Bit 7 = LSB)
9400
EFME and RSYE detected at RBE
9500
Can't start RSVP
9600
Can't detect (I-1) block at WR, WTM, and ERS
9610
Slow end after I-1 block
9620
BID Miscompare on write
9630
WRE and FWRE not equal at
9802
Tape Mark found on Space Block
9803
File Protected Tape
9900
Out of data block sequence
9910
RDEND time-out after DPOST is detected
9921
Invalid WRAP Mark
9922
WRAP Mark detected on 18 track tape
9930
Not capable
9940
IBG not detected
9960
IBG not detected
9970
Data block not found
April 1997
Table D-2. Formatter Error Recovery (Continued)
DESCRIPTION
CG00000-011503 REV. A
FAULT SYMPTOM CODES
BYTES
E.R.P.A.
29-39
GROUP
25
04
25
04
25
04
25
04
25
04
25
04
25
04
25
04
25
01
25
01
47
04
25
04
25
04
25
07
25
01
C0
08
30
01
23
07
23
04
25
04
2E
04
2E
04
25
01
41
01
44
08
D-5