11.1 Asynchronous oscillation (OS, OSP1, OSP2, OST1, OST2, OSCTRL, OSNSC, OSE, OSB)
Example 2: Oscillation with online modification of the reversal position
The setting data necessary for asynchronous oscillation can be set in the part program.
If the setting data are described directly in the program, the change takes effect during
preprocessing. A synchronized response can be achieved by means of a preprocessing stop
(
STOPRE
Program code
$SA_OSCILL_REVERSE_POS1[Z]=-10
$SA_OSCILL_REVERSE_POS2[Z]=10
G0 X0 Z0
WAITP(Z)
ID=1 WHENEVER $AA_IM[Z] < $$AA_OSCILL_REVERSE_POS1[Z] DO $AA_OVR[X]=0
ID=2 WHENEVER $AA_IM[Z] < $$AA_OSCILL_REVERSE_POS2[Z] DO $AA_OVR[X]=0
OS[Z]=1 FA[X]=1000 POS[X]=40
OS[Z]=0
M30
Further information
Oscillating axis
The following apply to the oscillating axis:
● Every axis may be used as an oscillation axis.
● Several oscillation axes can be active at the same time (maximum: the number of the
● Linear interpolation
The oscillating axis can:
● Act as an input axis for dynamic transformation
● Act as a guide axis for gantry and coupled-motion axes
● Be traversed:
Job planning
Programming Manual, 07/2010, 6FC5398-2BP40-0BA0
).
positioning axes).
is always active for the oscillating axis – irrespective of the G
G1
command currently valid in the program.
– Without jerk limit (
BRISK
or
– With jerk limit (
SOFT
or
– With acceleration curve with a knee (as positioning axes)
)
)
Oscillation
Comments
; If the actual value of
the oscillating axis has
exceeded the reversal
point, then the infeed
axis is stopped.
; Activate oscillation.
; Deactivate oscillation.