Siemens SINUMERIK 828D Programming Manual page 268

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

Special Motion Commands
4.8 Extended measuring function (MEASA, MEAWA, MEAC) (option)
Operating mode
The first digit (tens decade) of the operating mode selects the required measuring system. If
only one measuring system is installed, but a second programmed, the installed system is
automatically selected.
The second digit (units decade) selects the required measuring mode. The measuring
process is thus adapted to the options supported by the relevant control:
● Mode 1
● Mode 2
● Mode 3
Note
No more than two trigger events can be programmed if two measuring systems are in
use.
Measuring with and without deletion of distance-to-go
When command
measured values have been recorded.
The
position always needs to be approached.
268
Trigger events are evaluated in the chronological sequence in which they occur. When
this mode is selected, only one trigger event can be programmed for six-axis modules. If
more than one trigger event is specified, the mode selection is switched automatically to
mode 2 (without message).
Trigger events are evaluated in the programmed sequence.
Trigger events are evaluated in the programmed sequence but there is no monitoring of
trigger event 1 at START.
is programmed, the distance-to-go is not deleted until all required
MEASA
function is used in the case of special measuring tasks where a programmed
MEAWA
Programming Manual, 07/2010, 6FC5398-2BP40-0BA0
Job planning