No internal preprocessing stop is generated when these variables are read.
Note
A preprocessing stop must be programmed with
program. The system will otherwise read false values.
Syntax
MEAS=<TE> G... X... Y... Z...
MEAW=<TE> G... X... Y... Z...
Significance
MEAS
MEAW
<TE>
G...
X... Y... Z...
Example
Program code
N10 MEAS=1 G1 F1000 X100 Y730 Z40
...
Job planning
Programming Manual, 07/2010, 6FC5398-2BP40-0BA0
4.7 Measurements with touch trigger probe (MEAS, MEAW)
Command: Measuring with deletion of distance-to-go
Effective:
non-modal
Command: Measuring without deletion of distance-to-go
Effective:
non-modal
Trigger event to initiate measurement
Type:
INT
Range of values: -2, -1, 1, 2
Note:
There are up to a maximum of 2 probes
(dependent on configuration level).
Significance:
(+)1
Rising edge of probe 1 (measuring input 1)
-1
Falling edge of probe 1 (measuring input 1)
(+)2
Rising edge of probe 2 (measuring input 2)
-2
Falling edge of probe 2 (measuring input 2)
Note:
There are up to a maximum of 2 probes (dependent on configuration
level).
Type of interpolation, e.g.
End point in Cartesian coordinates
Special Motion Commands
at the appropriate position in the
STOPRE
,
,
or
G0
G1
G2
G3
Comment
; Measurement block with probe at first
measuring input and linear
interpolation. A preprocessing stop is
automatically generated.
261