Siemens SINUMERIK 828D Programming Manual page 305

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

$P_CHBFRAME[n] Current channel basic frames
System variable
frame field elements. The resulting complete basic frame is calculated in the channel as a
result of the write operation. Whenever a basic frame is written, the complete basic frame is
calculated again.
$P_BFRAME Current first basic frame in the channel
The predefined frame variable
frame with the field device of 0, which is valid in the channel, in the parts program. The
written basic frame is immediately included in the calculation.
$P_UBFR
there is no channel-specific basic frame, an alarm is issued at read/write: "Frame: instruction
not permissible".
$P_ACTBFRAME Complete basic frame
The
read-only.
$P_ACTFRAME
$P_NCBFRAME[0]
Job planning
Programming Manual, 07/2010, 6FC5398-2BP40-0BA0
$P_CHBFRAME[n]
is identical to
$P_CHBFR[0]
variable determines the chained complete basic frame. The variable is
$P_ACTFRAME
corresponds to
:
:
...
$P_NCBFRAME[n]
can be used to read and write the current channel basic
can be used to read and write the current basic
$P_BFRAME
. The system variable always has a valid default value. If
:
$P_CHBFRAME[0]
Coordinate transformation (FRAMES)
5.7 NCU global frames
:
:
...
$P_CHBFRAME[n]
.