10. 4 Insert type options
This inverter is equipped with two option slots (A, B) as standard. The option 3 slot adapter (option) can be
mounted.
10. 4. 1
Cassette options are available as shown in the next table.
■ Cassette options
Name
I/O extension (1)
I/O extension (2)
Digital encoder
Resolver
Safety module
PROFINET
EtherCAT
PROFIBUS-DP
9
DeveceNet
CANopen
10
10. 4. 2
Prohibited
Mandatory
action
Mounting/removing methods of a cassette option to the option slot A, B are as follows.
When using the option slot 3, refer to [10. 4. 3].
10. Selection and installation of peripheral devices
Insert type options and functions
Specification
6x digital input
2x digital output
2x analog input
3x 1a relay
RS422 Line receiver
Resolver
SS1, SS2, SOS, SBC, SMS, SLS,
SDI, SSM
PROFINET interface
EtherCAT interface
PROFIBUS-DP interface
DeviceNet interface
CANopen interface RJ45
D-sub
Open style
Mounting/removing insert type options
• Do not connect any communication options other than supported by option slots.
It can cause failure and accident.
• Mounting/removing options should be performed 15 minutes or more after the power is shut off,
and checking the charge lamp of the inverter is OFF.
The inverter and options may be damaged.
• Do not use tools for mounting/removing options.
The inverter and options may be damaged.
Type-form
ETB013Z
ETB014Z
VEC008Z
VEC010Z
SFT001Z
PNE001Z
IPE003Z
PDP003Z
DEV003Z
CAN001Z
CAN002Z
CAN003Z
WARNING
10-14
E6582062
Slot availability
Remarks
A, B, C
A, B ,C
B
B
Coming soon
C
Coming soon
A
A
Coming soon
A
Coming soon
A
Coming soon
A
Coming soon