6. 30. 3

Retaining trip types

<F602: Trip record retention>
■ Function
Trip can be reset by turning power off, but you can set to retain details about trip occurrence even
when power is turned off.
After power off, the saved trip type will be displayed after turning power on again. If trip factor is
remaining, however, the trip will occur again.
■ Parameter setting
Title
Parameter name
F602
Trip record retention
■ Selecting a setting value
0: Clear at power off
Reset the trip at power off. Trip type will not be retained after turning power on again.
1: Retain at power off
The following shows how the inverter operates after power off.
Trip has occurred
0: Clear at power off
1: Retain at power off
Reset at panel
Completion of reset
or terminal
Reset by turning
If trip factor is
power off, then
remaining
turning it back on
If trip factor is
cleared
6-121
STOP
F602 : Trip record retention
0: Clear at power off
1: Retain at power off
Adjustment range
Normal operation
Trip again
- Display of the cause
- Failure signal FL enabled
Retain trip state
- Display of the cause
- Failure signal FL disabled