Communication
Title
No.
F295
0295
F297
0297
1
F298
0298
F300
0300
F301
0301
F302
0302
F303
0303
9
11
F304
0304
F305
0305
F306
0306
11. Table of parameters
Parameter name
Adjustment range
0: Disabled
Bumpless
1: Enabled
Parameter for
-
manufacturer
Parameter for
-
manufacturer
Depending on capacity
Carrier frequency
1
*
0: Disabled
1: Power failure
2: Terminal ST On/Off
Auto-restart
3: Terminal ST On/Off or
power failure
4: At startup
0: Disabled
1: Regenerative power
ride-through
2: Deceleration stop at
Regenerative power
power failure
ride-through
3: Synchronized Acc/
Dec (TB)
4: Synchronized Acc/
Dec (TB + power
failure)
0: Disabled
Retry
1 - 10
0: Disabled
1: Enabled, OLr trip
2: Enabled, No OLr trip
3: Enabled (except
during ST OFF), OLr
trip
4: Enabled (except
during ST OFF), No
OLr trip
Dynamic braking,
5: Enabled (except
OLr trip
during trip), OLr trip
6: Enabled (except
during trip), No OLr
trip
7: Enabled (except
during trip & ST OFF),
OLr trip
8: Enabled (except
during trip & ST OFF),
No OLr trip
0: Enabled
1: Disabled
Overvoltage limit
2: Enabled (quick
operation
deceleration)
3: Enabled (dynamic
quick deceleration)
Parameter for
-
manufacturer
Minimum
setting unit
Unit
(Panel/Commu-
nication)
-
-
-
-
-
-
kHz
-
-
-
-
Times
-
-
-
-
-
-
11-14
E6582062
Write
during
Default
User
Reference
run-
setting
setting
*6
ning
0
Y
[6. 13]
-
-
-
-
[2. 4. 1]
Y
[2. 4. 3]
*1
[6. 14]
0
N
[5. 3. 2]
0
N
[6. 15. 2]
0
Y
[6. 15. 3]
0
N
[6. 15. 4]
2
N
[6. 15. 5]
-
-
-
-
-