F135
0135
F136
0136
1
F137
0137
F138
0138
F139
0139
F140
0140
F141
0141
F142
0142
F143
0143
F144
0144
9
F145
0145
F146
0146
11
F147
0147
F148
0148
F149
0149
11. Table of parameters
Parameter name
Adjustment range
Terminal R1 delay
0.0 - 60.0
time
Terminal R2 delay
0.0 - 60.0
time
Terminal FP
function 2
*5
0 - 255
Terminal R1
function 2
0: F130 and F137, F133
and F138
1: F130 and F137, F133
Terminal FP, R1
or F138
logic select
2: F130 or F137, F133
and F138
3: F130 or F137, F133
or F138
Terminal F
1 - 1000
response time
Terminal R
1 - 1000
response time
Terminal RES
1 - 1000
response time
Terminal S1
1 - 1000
response time
Terminal S2-S5
1 - 1000
response time
Terminal DI11-DI16
1 - 1000
response time
0: Digital input.
Terminal S4 input
1: Pulse train input
select
2: PG input
0: Digital input.
Terminal S5 input
1: Pulse train input
select
2: PG input
1: Voltage input (0-10 V)
2: Voltage input
(-10 to +10V)
3: Current input
(0-20 mA)
Terminal AI4 input
4: PTC input
select
5: PT100 (2-wire) input
6: PT100 (3-wire) input
7: PT1000 (2-wire) input
8: PT1000 (3-wire) input
9: KTY84 input
1: Voltage input (0-10 V)
2: Voltage input
(-10 to +10V)
3: Current input
(0-20 mA)
Terminal AI5 input
4: PTC input
select
5: PT100 (2-wire) input
6: PT100 (3-wire) input
7: PT1000 (2-wire) input
8: PT1000 (3-wire) input
9: KTY84 input
Minimum
setting unit
Unit
(Panel/Commu-
nication)
s
s
-
-
-
-
-
-
ms
ms
ms
ms
ms
ms
-
-
-
-
-
-
-
-
11-8
E6582062
Write
during
Default
User
Reference
run-
setting
setting
*6
ning
0.0
N
0.0
N
255
N
255
N
[7. 2. 2]
0
N
1
N
1
N
1
N
[7. 2. 1]
1
N
1
N
1
N
0
N
[6. 6. 4]
[7. 2. 1]
0
N
1
N
[6. 2. 4]
[6. 6. 2]
[6. 30. 19]
[7. 2. 1]
1
N