11. Table of parameters
Symbol
Function
SRVL
During servo lock
For input cumulative
IPU
power
SMPA
Shock monitoring alarm
Number of external
ENSA
equipment starting alarm
VFS1
V/f switching status 1
VFS2
V/f switching status 2
FAL
Cooling fan fault alarm
Embedded Ethernet com-
ETHE
munication time-out
CLD1
Calendar 1
CLD2
Calendar 2
CLD3
Calendar 3
CLD4
Calendar 4
PID2
During PID2 control
During External PID3
PID3
control
External PID3 deviation
PID3L
limit
During External PID4
PID4
control
External PID4 deviation
PID4L
limit
PMPC
Pump control
MYF1
My function output 1
MYF2
My function output 2
MYF3
My function output 3
MYF4
My function output 4
MYF5
My function output 5
MYF6
My function output 6
MYF7
My function output 7
MYF8
My function output 8
MYF9
My function output 9
MYF10
My function output 10
MYF11
My function output 11
MYF12
My function output 12
MYF13
My function output 13
MYF14
My function output 14
MYF15
My function output 15
MYF16
My function output 16
AOFF
Always OFF
Action
ON: During servo lock
ON: Input cumulative power unit reach
ON: Current / torque value reach the shock monitoring
detection condition
ON: Number of starting of external equipment is <F658:
Number of external equipment starting alarm> or more
ON: V/f switching status 1
ON: V/f switching status 2
ON: Cooling fan fault
ON: Embedded Ethernet communication time-out
ON: Calendar 1
ON: Calendar 2
ON: Calendar 3
ON: Calendar 4
ON: During PID2 control
ON: During External PID3 control
ON: Within the setting value of <A346: PID3 deviation upper-
limit>, <A347: PID3 deviation lower-limit>
ON: During External PID4 control
ON: Within the setting value of <A376: PID4 deviation upper-
limit>, <A377: PID4 deviation lower-limit>
ON: For pump operation
ON: My function output 1
ON: My function output 2
ON: My function output 3
ON: My function output 4
ON: My function output 5
ON: My function output 6
ON: My function output 7
ON: My function output 8
ON: My function output 9
ON: My function output 10
ON: My function output 11
ON: My function output 12
ON: My function output 13
ON: My function output 14
ON: My function output 15
ON: My function output 16
Always OFF
11-64
E6582062
Reference
[7. 2. 2]
[6. 30. 21]
[7. 2. 2]
[7. 2. 2]
[6. 30. 11]
[7. 2. 2]
[7. 2. 2]
[7. 2. 2]
-