Toshiba TOSVERT VF-AS3 Instruction Manual page 390

Industrial inverter (for 3-phase motors)
Hide thumbs Also See for TOSVERT VF-AS3:
Table of Contents

Advertisement

■ Setting example
<F681>="1", <F691>="1", <F692>= "0" (%)
Analog output current (mA)
20
0
<F681>="1", <F691>="1", <F692>= "100" (%)
4
Analog output current (mA)
4
20
<F692>
6
0
Set the inclination of analog output with <FM: Terminal FM adjustment> and <F671: Terminal AM
adjustment>. For details of how to adjust, refer to [5. 1. 6].
9
Reference
6. [Advanced] How to use parameters
<FM>
Internal calculated
value
0
100%
:
<FM>
Large
Internal calculated
value
0
100%
• How to operate the operation panel -> Refer to [3. 1. 1].
• How to switch display mode on the operation panel -> Refer to [3. 1. 2].
• Procedure to change parameter setting -> Refer to [4. 2. 3]
• Details on operation by external signals -> Refer to [Chapter 7].
<F681>="1", <F691>="1", <F692>= "20" (%)
Analog output current (mA)
20
4
<F692>
0
<F681>="1", <F691>="0", <F692>= "100" (%)
Analog output current (mA)
20
<F692>
4
0
6-162
E6582062
<FM>
Internal calculated
value
100%
:
<FM>
Small
Internal calculated
value
100%

Hide quick links: