11. Table of parameters
Symbol
Function
3-wire operation hold/
HD
stop
PID differential/integral
IDC
reset
PIDSW
PID plus/minus switching
FORCE
Forced run
FIRE
Fire speed run
DWELL
Dwell operation
KEB
Synchronized Acc/Dec
MYF
My function start
AUTT
Offline auto-tuning
Speed control gain
SGSW
switching
SRVL
Servo lock
SIMP
Simple positioning
Cumulative power moni-
CKWH
tor clear
TRACE
Trace trigger
Light-load high-speed
HSLL
operation inhibited
HDFP
Terminal FP output hold
HDR1
Terminal R1 output hold
HDR2
Terminal R2 output hold
UP
Terminal Up frequency
DOWN
Terminal Down frequency ON: Frequency command decreased
Terminal Up, Down fre-
CLR
quency clear
DANC
Dancer correction OFF
FRR
Coast stop
FR
Fwd/Rev
RS
Run/Stop
Commercial powr run
CPSW
switching
Action
ON: Forward run (F), Reverse run (R) held, 3-wire operation
OFF: Deceleration stop
ON: PID differential/integral cleared
ON: Plus/minus characteristics of <F359: PID control 1>
setting
OFF: Characteristics of <F359: PID control 1> setting
ON: Forced run, continues in a slight failure condition (Set
<F650: Forced run> = "1: Enabled". Frequency command
value = <F294: Preset speed 15 / Forced run speed>.)
*Stop with power off
ON: Fire speed run (Set <F650: Fire speed run> = "1:
Enabled". Frequency command value = <F294: Preset speed
15 / Forced run speed>.)
*Stop with power off
ON: Dwell operation (Stop acceleration and deceleration and
run the motor at a constant speed)
ON: Deceleration stop with synchronizing at power failure
ON: My function start (When <A977: My function> = "1:
Enabled by permission signal")
<F400> = "3" ON: Offline auto-tuning executed
<F400> = "6" ON: Offline auto-tuning executed at run
command while this signal is ON.
<F400> = "7" ON: Offline auto-tuning executed only for
<F402> at run command while this signal is ON.
ON: Use F463-F465
OFF: Use F460-F462
ON: Servo lock
ON: Simple positioning operation
ON: Clear cumulative power (kWh) monitor display
ON: Trace trigger (start) signal
ON: Light-load high-speed operation inhibited
OFF: Light-load high-speed operation permitted
ON: Terminal [FP] is held ON once turned ON
ON: Terminal [R1] is held ON once turned ON
ON: Terminal [R2] is held ON once turned ON
ON: Frequency command increased
OFF-> ON: Clear Terminal Up, Down frequency command
ON: Dancer correction OFF
ON: Coast stop (gate OFF)
ON: Forward command, OFF: Reverse command
ON: Run command, OFF: Stop command
ON: Commercial power run, OFF: Inverter run
11-58
E6582062
Reference
[7. 2. 1]
[5. 2. 8]
[7. 2. 1]
[7. 2. 1]
[6. 12. 2]
[6. 31]
[7. 2. 1]
[6. 19]
[7. 2. 1]
[7. 2. 1]
[6. 23. 1]
[6. 23. 2]
[7. 2. 1]
[7. 2. 1]
[6. 36]
[7. 2. 1]
[7. 2. 1]
[6. 6. 5]
[7. 2. 1]
[7. 2. 1]
[6. 34. 8]
[7. 2. 1]
[7. 2. 1]
[6. 20]
[7. 2. 1]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents