Toshiba TOSVERT VF-AS3 Instruction Manual page 511

Industrial inverter (for 3-phase motors)
Hide thumbs Also See for TOSVERT VF-AS3:
Table of Contents

Advertisement

Communication
Title
Parameter name
No.
Load sharing gain
F424
0424
input
Fwd speed limit
F425
0425
input
Fwd speed limit
F426
0426
level
Rev speed limit
F427
0427
input
Rev speed limit
F428
0428
level
Speed limit center
F430
0430
value input select
Speed limit center
F431
0431
value
F432
0432
Speed limit band
Rotation direction
F435
0435
limit during torque
control
Power running
F440
0440
torque limit input
select 1
Power running
F441
0441
torque limit level 1
Adjustment range
Unit
0: -
1: Terminal RR
2: Terminal RX
3: Terminal II
4: Terminal AI4 (option)
5 - 11: -
12: F725
13 - 19: -
20: Embedded Ethernet
-
21: RS485
communication
connector 1
22: RS485
communication
connector 2
23: Communication
option
0: -
1: Terminal RR
2: Terminal RX
3: Terminal II
-
4: Terminal AI4 (option)
5 - 11: -
12: F426
0.0 - UL
Hz
0: -
1: Terminal RR
2: Terminal RX
3: Terminal II
-
4: Terminal AI4 (option)
5 - 11: -
12: F428
0.0 - UL
Hz
0: -
1: Terminal RR
2: Terminal RX
3: Terminal II
-
4: Terminal AI4 (option)
5 - 11: -
12: F431
0.0 - FH
Hz
0.0 - FH
Hz
0: Fwd/Rev permit
1: Command direction
-
permit
0: -
1: Terminal RR
2: Terminal RX
3: Terminal II
-
4: Terminal AI4 (option)
5 - 11: -
12: F441
0.0-249.9
%
250.0: Disabled
11-23
Write
Minimum
during
setting unit
Default
run-
(Panel/Commu-
setting
*6
nication)
ning
-
0
Y
-
0
Y
50.0/
Y
*2
60.0
-
0
Y
50.0/
Y
*2
60.0
-
0
Y
0.0
Y
0.0
Y
-
0
Y
-
12
Y
250.0
Y
11. Table of parameters
E6582062
User
Reference
setting
1
[6. 24. 3]
3
9
[6. 24. 2]
10
11
[6. 24. 1]
[6. 25. 1]
[6. 25. 1]
[6. 25. 3]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents