Toshiba TOSVERT VF-AS3 Instruction Manual page 184

Industrial inverter (for 3-phase motors)
Hide thumbs Also See for TOSVERT VF-AS3:
Table of Contents

Advertisement

4: Clear past trips
Initialize (clear) the history information of eight past trips.
No parameter is changed.
When you select the setting and press the [OK] key, nothing appears momentarily, the same content
displayed at power on appears, and the mode enters [Standard mode].
5: Clear cumulative run time
Clear cumulative run time to 0.
When you select the setting and press the [OK] key, nothing appears momentarily, the same content
displayed at power on appears, and the mode enters [Standard mode].
6: Initialize typeform
Clear a trip if the type error "EtyP" occurs.
However, if it occurs, contact your Toshiba distributor.
4
When you select the setting and press the [OK] key, nothing appears momentarily, the same content
displayed at power on appears, and the mode enters [Standard mode].
5
7: Store user settings
Store the setting values of all current parameters.
8: Rewrite user settings
Rewrite the setting values of the parameters stored in "7: Store user settings" to the inverter.
You can use parameter initial settings specific for users with "7: Store user settings" and "8: Rewrite
user settings."
9: Clear cumulative fan run time
9
Clear cumulative fan run time to 0.
Set it, for example, when you have replaced the cooling fan.
When you select the setting and press the [OK] key, nothing appears momentarily, the same content
displayed at power on appears, and the mode enters [Standard mode].
12: Clear number of starting
Clear the values on the monitor to 0 for the number of starting, the number of forward starting, and
the number of reverse starting.
When you select the setting and press the [OK] key, nothing appears momentarily, the same content
displayed at power on appears, and the mode enters [Standard mode].
13: Default setting 2 (complete initialization)
Return all parameters to their default settings at a time.
When you select the setting and press the [OK] key, "Init" blinks in the main area and "Initializing"
appears under it for a while.
They disappear momentarily, the same content displayed at power on appears, and the mode
enters [Standard mode].
All parameters are returned to their default settings, and the history data of past trips is also cleared.
5. [Fundamental operation] How to use parameters
5-34
E6582062