11. Table of parameters
Symbol
Function
E
Emergency off trip
RETRY
During retry
PTNS
Pattern operation end
PIDL
PID deviation limit
RUN
Run/Stop
HFL
Serious failure
LFL
Slight failure
Commercial power/
CPSW1
Inverter Switching 1
Commercial power/
CPSW2
Inverter Switching 2
FAN
During cooling fan run
JOG
During jog run
JBM
During terminal run
Cumulative run time
COT
alarm
Communication option
COMOP
communication time-out
FR
Fwd/Rev run
RDY1
Ready for run 1
RDY2
Ready for run 2
BR
During brake
PAL
During alarm or pre-alarm ON: Alarm or pre-alarm occuring
FSL
During Fwd speed limit
RSL
During Rev speed limit
HLTH
Inverter healthy output
RS485 communication
COME
time-out
DATA1
Designated data bit 0
DATA2
Designated data bit 1
LLD1
Light load detection 1
HLD
Heavy load detection
During positive torque
PTL
limit
During negative torque
MTL
limit
For external relay of rush
RCRY
current suppression
FL4
Failure signal 4
Action
ON: During emergency off trip ("E" is displayed)
ON: During retry
ON: All pattern operation end
ON: Within the setting value of <F364: PID1 deviation upper-
limit>, <F365: PID1 deviation lower-limit>
ON: During run or DC braking, OFF: During stop
*1
ON: At trip
, OFF: Other than those trip above
ON: At trip ("OC1", "OC2", "OC3", "OP1", "OP2", "OP3",
"OH", "OL1", "OL2", "OL3", "OLr")
OFF: Other than those trip above
ON: For inverter run
ON: For commercial power run
ON: During cooling fan run
ON: During jog run
ON: During terminal run, OFF: Other than terminal run
ON: Cumulative operation time is <F621: Cumulative run
time alarm > or more
ON: Time-out of communication option occurs (held until
reset)
ON: During reverse run, OFF: During forward run
* Command direction or OFF during stop
ON: Run when frequency command is ON
ON: Run when ST, RUN, or frequency command is ON
ON: Brake, OFF: Break release
ON: <F426: Fwd speed limit level> or more (Torque control)
ON: <F428: Rev speed limit level> or more (Torque control)
Output while switching ON and OFF over at every 1 sec. (to
check inverter soundness)
ON:RS485 communication time-out
ON: bit0 of FA50 is ON, OFF: bit0 of FA50 is OFF
ON: bit1 of FA50 is ON, OFF: bit1 of FA50 is OFF
ON: Under heavy load torque(<F335> to <F338>)
ON: Heavy load torque(<F335> to <F338>)or more
ON: During positive torque limit
ON: During negative torque limit
ON: For external relay of rush current suppression
ON: During trip (including retry waite time)
11-62
E6582062
Reference
[7. 2. 2]
[6. 28]
[7. 2. 2]
[7. 2. 2]
[6. 30. 11]
[7. 2. 2]
[7. 2. 2]
[6. 30. 12]
[7. 2. 2]
[7. 2. 2]
[6. 38. 1]
[7. 2. 2]
[7. 2. 2]
[6. 15. 3]
[7. 2. 2]