5. 2. 10
Mandatory
action
<SEt: Region setting check>
4
Basic parameter
5
■ Function
When you select a region using in the setup menu at initial Power on, parameters such as the base
frequency of the motor is set automatically according to the selected region.
You can check the region that has been set or reset it by starting the setup menu.
9
■ Parameter setting
Title
SEt
■ Selecting a setting value
0: Setup menu starting
The setup menu to select the region where the inverter is used is started.
When you select the region, parameters such as the base frequency and the base frequency
voltage of the motor that are described on the separate table are automatically set.
5. [Fundamental operation] How to use parameters
Automatic setting of main parameters by region
used
• Make sure to set the setup menu correctly.
If you set the setup menu incorrectly, this will damage the inverter or cause the inverter to
perform unexpected movement.
Parameter name
Region setting check
WARNING
SEt
0: Setup menu starting
1: Japan (read only)
2: Mainly North America (read)
3: Mainly Asia (read only)
4: Mainly Europe (read only)
Adjustment range
0: Setup menu starting
1: Japan (read only)
2: Mainly North America (read only)
3: Mainly Asia (read only)
4: Mainly Europe (read only)
5: Mainly China (read only)
5-62
E6582062
STOP
0.0Hz
15:23
:Region Setting check
Default
setting
0