APOSS Software Messages

The APOSS software messages are arranged in
alphabetical order.
Compilation error ..
Compilation error(s): program not saved!
A file is always compiled first and then saved. If
you want to save the program, for example in the
menu Controller → Programs → Save program and
a syntax error is found during compilation this
message will be displayed.
Start the → Syntax Check in the menu
Development, correct the syntax error and then
save the program.
Connection already exists
Connection to .. already exists - change to
new Window?
When opening a new window, or when trying to
connect a window with a controller that is already
linked to a window.
Yes: The controller is disconnected from the old
window and linked to the new window.
No:
The controller stays connected to the old
window. The new window is not linked to a
controller.
Connector pin is not valid
Connector pin is not valid in line .. column ..
An illegal combination or a pin number which
cannot be set is used with the OUT command.
Controller is executing
Controller is executing a program or
command!
When the controller is executing a command or a
program it is not available for additional com-
mands. You must → Break [Esc] the new command
and re-start it once the previous command has
been completely executed.
Error in .. part of file
Error in array part of file
__ Troubleshooting __
When re-saving a configuration (e.g. with
Controller → Parameters → Restore from file) the
computer recognizes that the data in the array
area is formatted incorrectly.
In order to be able to save a file, the following
conditions must be fulfilled:
– Identical software versions,
– same configuration (e.g. same number of axes),
In the case that arrays have already been inputted,
these must match the ones that are to be saved in
terms of type and size.
Error in axis parameter part of file
When re-saving a configuration (e.g. with
→ Restore from file) the computer recognizes that
the data in the area of the axis parameters is
formatted incorrectly. The parameter number and
the sequence be correct and numbering must be
continuous.
In order to be able to save a file, the following con-
ditions must be fulfilled:
– Identical software versions, that provides same
– same configuration.
Error in global parameter part of file.
When re-saving a configuration (e.g. with
→ Restore from file) the computer recognizes that
the data in the area of the global parameters is
formatted incorrectly. In order to be able to save a
file, the following conditions must be fulfilled:
– Identical software versions, that provides same
– same configuration (e.g. same number of axes).
Lost connection
Lost connection to ..!
If the FC 300 is turned off or the plug is pulled, etc.
the window is disconnected from the FC 300 and
the lost connection is registered.
Timeout
Timeout: no reply from controller
The FC 300 does not answer; check the connection.
®
MG.33.L5.02 – VLT
is a registered Danfoss trademark
number and order of the parameters,
number and order of the parameters,
259