Danfoss MCO 305 Design Manual page 179

Programmable motion controller
Hide thumbs Also See for MCO 305:
Table of Contents

Advertisement

MCO 305 Design Guide
Command
Description
TESTSETTIME
defines the sampling period for data
recording
TESTSETTYPE
defines "one time" or "cyclic"
recording
TESTSTART
starts the recording of a test run
TESTSTOP
stops the data recording
TIME
reads internal controller time
TRACKERR
queries actual position error of an
axis
_GETVEL
changes sample time for AVEL and
MAVEL
__ How to Program __
Syntax
TESTSETTIME ms
TESTSETTYPE type
TESTSTART n
TESTSTOP method
res = TIME
res = TRACKERR
var = _GETVEL t
®
MG.33.L5.02 – VLT
is a registered Danfoss trademark
Parameter
ms = sampling period in ms
type:
0 = one time recording
1 = cyclic recording
n = 0
The max. number of samples
is recorded, which fits into the
defined memory section.
n > 0
No. of samples to be recorded
method:
0 = stops immediately
t = sample time in ms