Danfoss MCO 305 Design Manual page 184

Programmable motion controller
Hide thumbs Also See for MCO 305:
Table of Contents

Advertisement

MCO 305 Design Guide
Synchronizing Commands
Commands to synchronize the slave with the master or the master simulation. (Group SYN)
Command
Description
DEFSYNCORIGIN
Defines master-slave relation for
the next SYNCP or SYNCM
command.
MOVESYNCORIGIN
Relative shifting of the origin of
synchronization.
PULSACC
Sets acceleration for master
simulation
PULSVEL
Sets velocity for master simulation.
SYNCM
Synchronization of angle/position
with marker correction.
SYNCMARKERSTART
Resets a marker or resets marker
handling.
SYNCP
Synchronization of angle/position.
SYNCSTAT
Queries flag for synchronization
status.
SYNCSTATCLR
Resetting of the flags MERR and
MHIT.
SYNCV
Synchronization of velocity.
184
__ How to Program __
Syntax
DEFSYNCORIGIN
master slave
MOVE SYNCORIGIN
mvalue
PULSACC a
PULSVEL v
SYNCM
SYNCMARKERSTART
restarttype
SYNCP
res = SYNCSTAT
SYNCSTATCLR value
SYNCV
®
MG.33.L5.02 – VLT
is a registered Danfoss trademark
Parameter
master = reference position in qc
slave = reference position
mvalue = Relative offset
a = acceleration in Hz/s
v = velocity in pulses per second
(Hz)
restarttype = 0 or 1
value =
8 = SYNCMMHIT
16 = SYNCSMHIT
32 = SYNCMMERR
64 = SYNCSMERR