MCO 305 Design Guide
MCO Advanced Settings, Parameter List
Par. No.
Parameter name
#
33-0*
Home Motion
33-00
HOME_FORCE
33-01
HOME_OFFSET
33-02
HOME_RAMP
33-03
HOME_VEL
33-04
HOME_TYPE
33-1*
Synchronization
33-10
SYNCFACTM
33-11
SYNCFACTS
33-12
SYNCPOSOFFS
33-13
SYNC ACCURACY
33-14
SYNCVELREL
33-15
SYNCMARKM
33-16
SYNCMARKS
33-17
SYNCMPULSM
33-18
SYNCMPULSS
33-19
SYNCMTYPM
33-20
SYNCMTYPS
33-21
SYNCMWINM
33-22
SYNCMWINS
33-23
SYNCMSTART
33-24
SYNCFAULT
33-25
SYNCREADY
33-26
SYNCVFTIME
33-27
SYNCOFFTIME
33-28
SYNCMFPAR
33-29
SYNCMFTIME
33-30
SYNCM MAXCORR
33-31
SYNCTYPE
default setting
246
__ Parameter Reference __
Parameter description
Force HOME
Zero Point Offset from
Home Position
Ramp for Home Motion
Velocity of Home Motion
Behavior during Home
Motion
Synchronization Factor
Master (M:S)
Synchronization Factor
Slave (M:S)
Position Offset for
Synchronization
Accuracy Window for
Position Synchronization
Relative Slave Velocity
Limit
Marker Number for Master
Marker Number for Slave
Master Marker Distance
Slave Marker Distance
Master Marker Type
Slave Marker Type
Master Marker Tolerance
Window
Slave Marker Tolerance
Window
Start Behavior for
Synchronization
Marker Number for Fault
Marker Number for Ready
Velocity Filter
Offset Filter Time
Marker Filter Configuration
Filter Time for Marker
Correction
Maximum Marker
Correction
Synchronization Type
[ ]
value for use in communication via serial communication port
®
MG.33.L5.02 – VLT
is a registered Danfoss trademark
Default
Changes
setting
during
operation
[0] not forced
'TRUE'
0 qc
TRUE
10
TRUE
10
TRUE
[0] Reverse +
TRUE
Index
1
TRUE
1
TRUE
0 qc
TRUE
1000 qc
TRUE
0 %
TRUE
1
TRUE
1
TRUE
4096
TRUE
4096
TRUE
[0] Enc. Z pos.
TRUE
[0] Enc. Z pos.
TRUE
0
TRUE
0
TRUE
[0] Start Funct.
TRUE
1
10
TRUE
1
TRUE
0 μ s
TRUE
0 ms
TRUE
[0] Marker
TRUE
Filter 1
0 ms
TRUE
[0] Off
TRUE
[0] Standard
TRUE
4-set-up
Conver-
Type
sion
index
2 set-ups
Uint8
2 set-ups
Int32
2 set-ups
Uint16
2 set-ups
Int16
2 set-ups
Uint8
2 set-ups
Int32
2 set-ups
Int32
2 set-ups
Int32
2 set-ups
Int32
2 set-ups
Uint8
2 set-ups
Uint16
2 set-ups
Uint16
2 set-ups
Uint32
2 set-ups
Uint32
2 set-ups
Uint8
2 set-ups
Uint8
2 set-ups
Uint32
2 set-ups
Uint32
2 set-ups
Uint16
2 set-ups
Uint16
2 set-ups
Uint16
2 set-ups
0
Int32
2 set-ups
Uint32
2 set-ups
Uint8
2 set-ups
Int32
2 set-ups
Uint32
2 set-ups
Uint8