MCO 305 Design Guide
__ APOSS Tools __
Poll Rate
The poll rate specifies how often the Oscilloscope will try to read data for polled curves from the controller
when an Oscilloscope "run" start been started. Care should be taken not to set this time shorter than
necessary as it can significantly increase demands on the PC processor, the controller processor, and the
communication network.
Sample Count
This is the default sample count to be used when new curves are added. The sample count is the maximum
number of points that the Oscilloscope will save for a curve before old points are discarded to make room
for new points. See also Properties → Source.
Event Time / Inhibit Time
This is the default PDO event time and the default PDO inhibit time to be used when new curves are being
added.
After a curve has been added, these values can be changed by using Properties → Source in the "Curve
Selection List".
Default Test Configuration
This set of parameters specifies the default values to be used by the Tune Oscilloscope.