MCO 305 Design Guide
Delete Programs all
Development → Delete Programs all will delete all programs saved on all controllers that share the same
connection interface as the controller connected to this APOSS Window (e.g. multiple controllers on a field
bus). Controllers connected using other interfaces are not affected.
Also note that programs will be deleted even on those controllers that are not currently connected to an
APOSS Window. As long as the controller is using the same connection interface and is within the original
connection ID scan range, then programs will be deleted. For example, if controllers 1 and 2 are both on a
field network but APOSS is currently only connected to controller 1, then Delete Programs all will still delete
programs on both controller 1 and 2.
This command is intended to be used in conjunction with Development → Download all.
Select Controller
If more than one controller is accessible from the
PC, then Development → Select controller can be
used to select the specific controller to which the
APOSS Window is to be connected. All currently
available controllers will be displayed in a tree view.
Select the desired controller and click on OK to
connect to that controller.
If no controllers are shown or the desired interface
is not present, then select the desired interface from
the Interface dropdown box and click on → Open
Interface. The desired interface can then be
selected. Note that choosing an interface in this way
does not change the default interface specified using
Settings → Interface.
If a controller is already connected to the APOSS Window, then Development → Select controller can be
used to switch the APOSS Window to another controller. Simply use the Select Controller dialog to select the
new controller. The existing connection to the previous controller will then be closed and a connection to the
new controller will be opened.
Since any specific controller can be connected to only one APOSS Window at a time, selecting a controller
that is already connected to another APOSS Window will cause that controller to be switched from the other
APOSS Window to this APOSS Window.
Close Interface / Close All Interfaces
If there is a controller currently connected in this APOSS Window, then → Close Interface can be used to
close the connections to all controllers that share the same connection interface as this controller. A
message will be displayed indicating which controller connections will be closed.
Close All Interfaces is similar to the Close Interface function except that all controllers on all connection
interfaces are closed.
68
__ PC Software Interface __
®