MCO 305 Design Guide
33-47 Size of Target Window
TESTWIN
Range [Unit]
0 – 10000 [qc]
0 = Off
TESTWIN must always be less than par. 33-46
TESTVAL.
Function
TESTWIN indicates the size of the target window. A
position is only viewed as reached when the refe-
rence-run (trapeze) is executed, the actual position
is within the window and the velocity is less than
par. 33-46 Target Window Limit Value (Precondition
I: TESTWIN and TESTTIM are activated.)
In this content the velocity is given as TESTVAL in
qc/TESTTIM.
The controller wait to execute the next command
until the actual position is within the target
window.
If TESTWIN is not active [0], then the target has
been reached if the set position is the target posi-
tion. However, this does not necessarily correspond
with the actual position of the drive.
NB!:
If the target window surrounding the end
position is selected to be too small, the
drive could move in a very small area
around the end position without reaching the target
window. Thus the program would be 'stuck' after
the corresponding positioning command.
A target window of [0] deactivates the monitoring
of the actual position and only monitors the com-
mand position.
NB!:
Modified handling of TESTWIN to adapt to
the needs of CANopen: If TESTTIM is set
but TESTVAL is not set, then the CANopen
case is assumed. In that case, it is checked if the
time within the TESTWIN is longer than TESTTIM.
If so, then the position has been reached. Other-
wise, the position has not been reached.
TESTWIN handling is modified starting with version
MCO 5.00.
default setting
__ Parameter Reference __
[ ]
value for use in communication via serial communication port
®
MG.33.L5.02 – VLT
is a registered Danfoss trademark
33-5* I/O Configuration
There is one parameter per input and output. One
function assigned to each input and output via this
parameter.
0
Digital Input Functions
Digital input function
No function
Home switch 'no'
Home switch 'nc'
Negative end switch 'no'
Negative end switch 'nc'
Positive end switch 'no'
Positive end switch 'nc'
Error clear 'no'
Error clear 'nc'
Break program exe 'no'
Break program exe 'nc'
Continue program exe 'no'
Continue program exe 'nc'
Start program exe 'no'
Start program exe 'nc'
Program select
X57 = all
*) X59/7,8 only if par. 33-60 IOMODE is set to [0].
You can program all digital inputs 1 – 10 (12) to
these functions:
– No function [0]: No reaction on signals from the
input_n.
– Home switch no [1]: Defines digital input_n of
MCO 305 as home switch. Behavior after
reaching see HOME_TYPE.
– Home switch nc [2]: Defines digital input_n as
home switch inverse. Behavior after reaching,
see HOME_TYPE.
– Negative end switch no [3]: Defines digital
input_n as the negative end switch.
– Negative end switch nc [4]: Defines digital
input_n as the negative end switch inverse.
– Positive end switch no [5]: Defines digital
input_n as the positive limit switch.
– Positive end switch nc [6]: Defines digital
input_n as the positive limit switch inverse.
Select
Terminal
[0]
X57, X59/7,8*
[1]
X57, X59/7,8*
[2]
X57, X59/7,8*
[3]
X57, X59/7,8*
[4]
X57, X59/7,8*
[5]
X57, X59/7,8*
[6]
X57, X59/7,8*
[7]
X57, X59/7,8*
[8]
X57, X59/7,8*
[9]
X57, X59/7,8*
[10]
X57, X59/7,8*
[11]
X57, X59/7,8*
[12]
X57, X59/7,8*
[13]
X57, X59/7,8*
[14]
X57, X59/7,8*
[15]
X57, X59/7,8*
231