MCO 305 Operating Instructions

APOSS Software Messages

The APOSS software messages are arranged in
alphabetical order. Letters following a % sign
represent variables which can be used in plain text
at the corresponding locations.
Compilation error(s): program not saved!
A file is always compiled first and then saved. If
you want to save the program, for example in the
menu Controller
Save program and a syntax
error is found during compilation this message will
be displayed.
Start the
Syntax Check in the menu
Development, correct the syntax error and then
save the program.
Connection to . . . already exists . . .
Connection to %d already exists [%s] -
change to Window?
When opening a new window, or when trying to
connect a window with a controller that is already
linked to a window.
Yes: The controller is disconnected from the old
window and linked to the new window.
No:
The controller stays connected to the old
window. The new window is not linked to a
controller.
Connector pin is not valid
Connector %d pin %d is not valid in line %d
column %d
An illegal combination or a pin number which
cannot be set is used with the OUT command.
46
__ Troubleshooting __
Controller is executing a program or command!
When the controller is executing a command or pro-
gram it is not available for additional commands.
You have to Break the new command and re-start it
once the previous command has been completely.
Error in array part of file
When re-saving a configuration (e.g. Controller
Parameters
recognizes that the data in the array area is for-
matted incorrectly.
In order to be able to save a file, the following con-
ditions must be fulfilled:
Error in axis parameter part of file
When re-saving a configuration (e.g. Controller
Parameters
cognizes that the data in the area of the axis para-
meters is formatted incorrectly. The parameter
number and the sequence must be correct and
numbering must be continuous.
In order to be able to save a file, the following con-
ditions must be fulfilled:
– Identical software versions, that provides same
– same configuration (e.g. same number of axes).
Error in global parameter part of file
When re-saving a configuration (e.g. Controller
Parameters
recognizes that the data in the area of the global
parameters is formatted incorrectly.
In order to be able to save a file, the following
conditions must be fulfilled:
– Identical software versions, that provides same
– same configuration (e.g. same number of axes).
Lost connection to ...
If the FC 300 is turned off or the plug is pulled, etc.
the window is disconnected from the FC 300 and
the lost connection is registered.
Timeout: no reply from FC
The FC 300 does not answer; check the connection.
MG.33.K2.02 – VLT is a registered Danfoss trademark
Restore from file) the computer
Identical software versions,
same configuration (e.g. same number of axes),
in the case that arrays have already been input-
ted, these must match the ones that are to be
saved in terms of type and size.
Restore from file) the computer re-
number and order of the parameters,
Restore from file) the computer
number and order of the parameters,